Fitting a later wiper motor to an early bracket
Fit a later-model wiper motor to the existing early-model metal bracket. The adapter plate and linkage allow mechanical installation. Set the motor electrically to its park position first before finally securing the drive.
Difficulty: 1/3 · Estimated time: 45 minutes, excluding removal of the wiper assembly from the car.
Parts and tools
Prepare the appropriate 12V motor and adapter kit 1106012, the original motor bracket and suitable wiper spindles/linkages 1106800 if the old parts cannot be reused. Check bearings, joints and retaining clips.



| Letter | Component |
|---|---|
| A | Adapter plate |
| B | Crank/linkage mechanism |
| C | Drive piece for the motor shaft |
| D | Blind rivets |
| E | Three motor mounting bolts |
| F | Self-locking motor shaft nut |
| G | Motor mounting washers |
| H and I | Wiper spindle washers; H is the thin lower washer |
Required: rivet gun, drill and 6 mm metal drill bit, suitable spanners and retaining-ring tools, 22 mm open-ended spanner, suitable electrical connections and a fused 12V test supply. An old two-terminal switch requires the appropriate relay 1101015.
Disconnect power while drilling, assembling and wiring. Clamp the bracket for drilling, wear eye protection and remove all burrs and swarf. Secure the motor firmly for electrical testing, keep fingers and clothing out of the drive and use fused wiring. The motor may automatically move to park as soon as power is connected.
1. Attach the adapter plate to the old bracket
Place adapter plate A correctly on the metal motor bracket and secure with rivets D as shown. Check its position before setting the rivets fully.



Mark the two additional motor mounting holes using the fitted plate. Drill the two indicated points with a 6 mm metal drill bit. Deburr and remove all swarf.




2. Prepare the motor and drive piece
Attach the motor to A with the three bolts E and three washers G at the three motor mounting points. Tighten evenly according to the kit instructions.


Place drive piece C on the crank of mechanism B. Secure the pin with its clip and check full engagement in the groove. Do not finally attach C to the motor shaft yet.



3. Electrically park the motor
This temporary connection applies to the motor shown. Check wire functions on other versions.
- Connect the white and grey motor wires together temporarily.
- Connect the black wire to negative/earth of the 12V supply.
- Connect the blue wire to fused positive.
- Let the motor stop itself in its park position.
- Switch off the supply and remove temporary connections before continuing mechanical assembly.


4. Fit wiper linkages and washers
Fit the linkage pieces/wiper spindles at the designated positions at both ends of B. Use suitable washers and retaining clips from kit 1106800 or checked, serviceable original parts. Check every clip for full retention.



Pass the wiper spindles through the motor bracket. Place the thin washer H below the bracket and washer I above. Fit the supplied nuts from above using the 22 mm spanner.

5. Secure the linkage in the correct park position
Place the bracket in the same orientation as the photo. The shorter part of B is to the left of the motor. Place C on the parked motor shaft: the crank mechanism pin is to the left of the motor shaft and B runs parallel to the bracket.


Secure the drive piece with self-locking nut F according to the kit instructions. No tightening torque is specified here.


6. Relay for an old two-terminal switch
Used directly with an old two-terminal switch, the new motor may stop anywhere on the screen. For the described combination, relay 1101015 provides the park function. Connect the blue motor wire to a fused permanent positive supply and black to earth.

| Connection | Connection according to diagram |
|---|---|
| Old switch supply | Ignition-switched positive |
| Other switch terminal | To relay 1 AND 5 |
| Relay 2 | Earth |
| Relay 3 | White motor wire |
| Relay 4 | Grey motor wire |
| Blue motor wire | Fused permanent positive |
| Black motor wire | Earth |
The diagram shows the underside of the relay and the rear of the switch. Numbers 1–5 apply to this relay version; do not map them visually onto another relay. Check the diagram on the housing. Remove the temporary white-grey bridge from step 3: the final circuit uses the relay.
Final checks
- Adapter and motor are secure; holes are deburred and all swarf removed.
- All clips and washers are correctly fitted, including H below and I above the bracket.
- Motor was parked before coupling and linkage positioned as shown.
- Wiring is fused, insulated and clear of moving parts.
- First carefully test free movement and park position without incorrectly positioned arms being able to strike the body.
- Fit the arms to suit the park position and test on a wet screen. Wipers must move freely and return to the bottom when switched off.